Chat with us, powered by LiveChat HUMIDITY AND PRECIPITATION LABORATORY | Writedemy

HUMIDITY AND PRECIPITATION LABORATORY

HUMIDITY AND PRECIPITATION LABORATORY

Question
HUMIDITY AND PRECIPITATION LABORATORY

1. Objectives

The objectives of this lab are to familiarize you with a few of the ways in which two common

meteorological variables (humidity and precipitation amount) are measured, and to assess the errors

implicit in the measurements.

2. Humidity

2.1: Home weather stations have relatively accurate capacitance humidity sensors. However, to a

meteorologist these are of limited utility because they can only give the indoor relative humidity (RH).

Nevertheless, by assuming that the mixing ratio is the same both inside and outside of the building, and

by measuring the RH inside and the temperatures (T) outside and inside, we can use the inside RH to

estimate the outside RH. Part of the lab will be to assess the validity of this assumption.

2.2: Specific tasks

• Compare the RHs of room air from the Vaisala Humicaps and the psychrometers. Take repeat

readings to assess reproducibility.

• Calibrate the Vaisala against the four saturated salt solutions.

• Test the hypothesis of conservation of water vapor by measuring the RH and T inside, with the

Vaisala, and then measuring the outside RH and T with the Vaisala.

3. Precipitation

The Davis gauge is designed to measure increments of 0.01 inches of rainfall. It would therefore be wise

to work in inches in this case and convert to millimeters in your analysis because the digitization works

better on the Davis using inches.

3.1: Calibrate a Davis tipping bucket rain gauge by determining the volume that each bucket of the gauge

holds. You can do this by using a pipette apparatus and slowly pouring a certain amount of water into

each bucket until it tips. Try at least 3 trials in each of the two buckets so that you can calculate simple

statistics. Also measure the diameter of the collection funnel for use in later calculations.

3.2 For the Davis tipping bucket gauge, determine the relationship between the true and measured (Davis)

rain rate, and to determine whether the measurement error changes with rain rate. Do this by pouring

measured volumes of water per unit time, using the buret, into the gauge. Use at least four different

pouring rates. Make sure to record the measured volume and the amount indicated on the Davis. The

lowest rate should be equivalent to ~10 mm hr-1 and the rates should be separated by at least a factor of

two. Without making a mess, try pouring in a measured amount of rain using a graduated beaker to

simulate rain at a very high rate to determine if the Davis gauge would see a tropical downpour.

1Humidity and Precipitation Lab Worksheet

Complete the following activities and turn your results as though you would a typical problem

set (i.e. no formal write-up required).

1) Capacitance Humidity (Vaisala) vs Psychrometer: Provide the mean and standard

deviation of your RH measurements using the Vaisala and the psychrometer. Are RH

values measured by each significantly different?

2) Calibration of the Vaisala RH Probes vs Salt Solutions: Produce a well-labeled

calibration figure, a linear regression, and total uncertainty in the Vaisala RH

measurements based on the results of that regression of calibration data. Comment on the

time response of the sensor.

3) Conservation of Water Vapor Test: Compare the measured outside RH with that

estimated from the inside measurements assuming conservation of mixing ratio. Is there a

bias? Give some reasoning for a bias if one is observed. In other words, what might cause

the assumption of constant water vapor concentration inside and outside to be invalid?

4) Tipping Bucket Volume Determinations: From 3.1 of the lab procedure, you can

calculate the mean and standard deviation of your bucket volumes. Assuming a normal

distribution, a value within three standard deviations has almost 100% probability of

occurrence. Using this information, deduce the lowest amount of rain (in millimeters)

measurable for each bucket of the Davis rain gauge.

5) Error in the Davis Tipping Bucket Gauge as a Function of Rain Rate: Convert the

volume of water that you measured in a given time into equivalent millimeters per hour

using knowledge of the collection area of the funnel. Use a linear regression to determine

the functional relationship between rain rate and observed rate from the Davis. Produce a

well-labeled calibration figure along with the linear regression and uncertainty analysis

results.

Our website has a team of professional writers who can help you write any of your homework. They will write your papers from scratch. We also have a team of editors just to make sure all papers are of HIGH QUALITY & PLAGIARISM FREE. To make an Order you only need to click Ask A Question and we will direct you to our Order Page at WriteDemy. Then fill Our Order Form with all your assignment instructions. Select your deadline and pay for your paper. You will get it few hours before your set deadline.

Fill in all the assignment paper details that are required in the order form with the standard information being the page count, deadline, academic level and type of paper. It is advisable to have this information at hand so that you can quickly fill in the necessary information needed in the form for the essay writer to be immediately assigned to your writing project. Make payment for the custom essay order to enable us to assign a suitable writer to your order. Payments are made through Paypal on a secured billing page. Finally, sit back and relax.

Do you need an answer to this or any other questions?

About Writedemy

We are a professional paper writing website. If you have searched a question and bumped into our website just know you are in the right place to get help in your coursework. We offer HIGH QUALITY & PLAGIARISM FREE Papers.

How It Works

To make an Order you only need to click on “Order Now” and we will direct you to our Order Page. Fill Our Order Form with all your assignment instructions. Select your deadline and pay for your paper. You will get it few hours before your set deadline.

Are there Discounts?

All new clients are eligible for 20% off in their first Order. Our payment method is safe and secure.

Hire a tutor today CLICK HERE to make your first order